Thursday 1 February 2018

Air humidity can be estimated by measuring

WONDERFUL DISCUSSION WITH SHRI JKP SIR UNDER KSS

Air humidity can be estimated by measuring
  • dry bulb temperature, and
  • wet bulb temperature
Humidity measurement - dry wet bulbe temperature meeter
Dry Bulb Temperature - Tdb - can be measured with a simple thermometer as shown above.
Wet Bulb Temperature - Twb - can be measured with a standard thermometer with some wet clothing, cotton or similar, around the bulb. Note that continuously air flow around the thermometer is important to evaporate water from the wet clothing and achieve a correct wet bulb temperature.
Sufficient air movement can be achieved with a sling thermometer or similar.
Relative humidity can be estimated from the tables below or alternatively from a psyhrometric or a Mollier diagram.

Example - The State of Air in the Mollier Diagram

If the dry bulb temperature of air is 19oC and the web bulb temperature is 12oC - then the state of air can be visualized in the Mollier diagram as indicated below.
  • the relative humidity is approximately 42%
  • the humidity ratio is approximately 0.0057 kgh2o/kgdry_air
Mollier diagram - state of air based on dry bulb and web bulb temperature

Relative Humidity - Temperature in Celsius

The table below can be used to estimate the relative humidity of air if dry and wet bulb temperatures are known.
Relative Humidity - RH (%)
Tdb Twb (oC)Dry Bulb Temperature - Tdb (oC)
1518202225273033
19091919292929393
28082838485858687
37173757677787980
46265676870717374
55357596164656769
64449525457596163
73642454751535558
82834384145475053
92127313439414548
101320252833364043
Relative moisture - dry and wet bulb temperature diagram - degrees Celsius

Example - Relative Humidity

If the dry bulb temperature of air is 18oC and the web bulb temperature is 12oC - then the difference between them is 6oC. By using the table above
  • the relative humidity is approximately 49%

Example - the State of Air in the Psychrometric Chart

The state of air with dry bulb temperature 75oF and wet bulb temperature 62.5oF can be visualized in thepsychrometric chart as indicated below.
  • the relative humidity is approximately 50%
  • the humidity ratio is approximately 65 grainsh2o/lbdry_air
Psychrometric chart - dry and wet bulb temperatures

Relative Humidity - Temperature in Fahrenheit

The table below can be used to estimate the relative humidity of air if dry and wet bulb temperatures are known.
Relative Humidity - RH (%)
Tdb Twb (oF)Dry Bulb Temperature - Tdb (oF)
6064687276808488
19495959596969696
29090909191929292
38485858687888889
47880818283848485
57375767879808081
66870727375767778
76366676971727374
85861636567687071
95457596163656668
104952555759616364
Dry and wet bulb temperature diagram - degrees Fahrenhei

No comments: